Add Simrad / Lowrance Camera

Overview

This guide explains how to set up the Simrad camera with BRNKL. Unlike some other cameras, the Simrad camera must be added manually using an RTSP URL.


Prerequisites

  • ✅ Supported:

    • Simrad IP CAM-1

    • Lowrance IP CAM-1


Install Camera

  1. Mount the camera according to the manufacturer’s instructions.

  2. Connect the camera to the vessel’s IP network.

  3. Ensure the camera is powered on during configuration.


Prepare Camera

  1. Connect a computer to the same network as the camera.

  2. Open a browser and navigate to the camera’s default IP address.

    • The camera ships with a static IP address (refer to the manufacturer’s documentation).

  3. Log in with the default credentials:

    • Username: admin

    • Password: (no password)

  4. Change the IP address so it matches your vessel’s network scheme:

    • Set IP Address Mode to Static.

    • Enter a valid IP address on your boat’s network.

    • Configure the Gateway Address to the IP of the MFD or Router that BRNKL is connected to.

    • Save and apply the settings.


Add Simrad Camera to BRNKL Device Manager

  1. Open BRNKL Device ManagerSettings > Cameras.

  2. Click + Add Camera.

  3. Select + RTSP URL.

  4. Enter the RTSP URL in the following format:

    rtsp://admin:1234@<ip address>:554/live/0/MAIN
    

    Replace <ip address> with the static IP you configured for the camera.

  5. Enter a descriptive name for the camera (e.g., Engine Room).

  6. Click Add.